What is Diesel Explosion Proof
(DX)?
DX is the
explosion protection for all types of Diesel Powered Industrial Equipment. By
enclosing or eliminating all ignition sources and regulating temperatures, DX
Equipment is safe for use in areas containing explosive or flammable materials.
The design and construction of Excalibur Miretti Group's DX Equipment permit their
classification as Diesel Explosion Proof (DX) with full certification and enable
their use in designated explosive and hazardous atmospheres
DX Advantage
Excalibur Miretti Group’s DX product line is Diesel Explosion Proof equipment
designed to operate in both indoor and outdoor hazardous applications. The most
powerful Explosion Proof equipment, DX is ideal for oil rigs, oil refineries,
petrochemical applications, aerospace facilities, military installations,
defense applications and pharmaceutical applications
Temperature
Controls
Heat generated by diesel equipment may cause gases and flammable materials to
ignite or explode. It is therefore necessary to reduce the temperature of DX
Equipment to less than the specified value for operation in a potentially
explosive atmosphere and to prevent any sparking from occurring. Excalibur
Miretti Group’s DX Equipment has protection controls for engine surface
temperature, exhaust temperature, fluid temperatures and brake temperatures.
For example, the Water Cooled Exhaust Gas Cooler, limits the surface and exhaust
temperatures to the specified temperature class.
Explosion
Proof Enclosures
Explosion Proof Enclosures protect all cabling, wiring, valves and electrical
components, ignition system, and battery.
An Explosion Proof
Enclosure is a case or housing that has been tested and approved to contain
electrical components or apparatus. Although the joints of Explosion Proof
enclosures will permit the entry of explosive vapors, the strength of the
enclosures must contain any internal explosion. The enclosures of Excalibur
Miretti Group DX Equipment have been hydrostatically tested for internal
explosive resistance to pressures in excess of requirements without failure.
Flame and
Spark Omission
Flames and sparks are ignition sources that must be prevented in hazardous
locations. Excalibur Miretti Group’s DX Equipment prevents flame or spark
omission from the exhaust and air intake systems with flame arrestors. The DX
exhaust system includes a first heat exchanger for cooling the exhaust fumes
prior to their passage through a flame arrester. The exhaust output from the
flame arrester is then passed through to a second heat exchanger. The output of
the second heat exchanger is then passed through a dry secondary cooler which
includes a spark arrestor. The air intake system also contains a flame arrestor.
Emission
Control
It is further necessary and desirable to reduce the pollutants emitted by
the diesel equipment and not add to the gases and flammable substances already
present. The flame arrester oxidizes the pollutants present in the exhaust
fumes with metal foils coated by a noble metal.
This eliminates the need for frequent cleaning and maintenance. Thus, the flame
arrester also functions as a remover of pollutants and is self cleaning.
The
flame arrestor on Excalibur Miretti Group’s DX Equipment is integrated with an
emission control device.
Automatic shutoffs
Automatic shutoffs serve as additional safeguards for diesel equipment.
Excalibur Miretti Group’s DX Equipment provides automatic shutoffs to ensure
against: engine over speed, low engine oil pressure and unacceptably hot
radiator water temperature. For example, a mechanical negative pressure system
with electrical switch prevents over speed condition by shutting off the air and
fuel system.
Worldwide Third Party Explosion Proof
Certifications
Excalibur
Miretti Group's DX Equipment is certified by Internationally Recognized
Testing Laboratories